Product information & resources

Product description

Expand to view the product description.

View description

Product description

Coloplast’s patented Torosa Saline-Filled Testicular Prosthesis aids in restoring natural appearance for adults and children missing one or two testicles due to congenital anorchism, monorchism, cryptorchidism, orchiectomy or other procedures. The weight, shape and soft texture are designed to mimic the natural testicles, and have high levels of patient satisfaction. (cf. 1)

Torosa features:

Weight, shape and texture of the prosthesis approximates a normal testicle, providing a more natural looking and feeling scrotum.
Suture tab enables physicians to secure the device in a set position, if desired, minimizing unwanted implant movement within the scrotum.
Self-sealing injection port for inflation

Product safety:

Based on available clinical trials and published data, the prostheses have a low incidence of infection, migration, displacement, extrusion, erosion, fibrous capsular contracture, hematoma, necrosis and reoperation. (cf. 1)
There were no reports of silicone-immunological adverse events in any core clinical trial subjects. (cf. 1)

Patient satisfaction:

The cosmetic benefits provided by testicular prostheses have been reported by numerous investigators to lead to psychological benefits and high levels of patient satisfaction. (cf. 2)

Physician Videos:

Click here: to view a collection of video clips designed to provide detailed information to physicians interested in learning more about Torosa testicular prostheses.

Important Safety Information


The Coloplast Torosa is intended for use when cosmetic testicular replacement is indicated i.e., in the case of agenesis or following the surgical removal of a testicle.


The implantation of testicular prostheses is contraindicated in the presence of infection or untreated neoplasm.


Implantation of a testicular prosthesis in patients with pre-existing varicoceles may result in persistent pain.  Testicular implants should not be considered lifetime implants due to the inherent nature of silicone implants, implant procedures, and potential individual psychological reactions.  This device contains silicone elastomer in a cured state.  The risks and benefits of implanting this device in patients with lupus, scleroderma, myasthenia gravis, or documented sensitivity to silicone should be carefully considered.  The issue of the possible relationship between silicone and various diseases has been and continues to be the subject of scientific and medical debate.  Sepsis, hemorrhage or thrombosis may result from the placement of any foreign object in the body. Use of an excessively large implant may result in tissue necrosis/thrombosis.  Excessive fibrous capsular formation or contracture oay occur around any implant placed in contact with soft tissues.  The incidence and severity of this occurrence may increase if postoperative local hematoma or infection occurs.


A thorough preoperative consultation should include a discussion between the patient and physician of all available treatment options and their risks and benefits.  The action of drugs (such as antimicrobials, chemotherapy agents or steroids) in contact with the prosthesis has not been tested by the manufacturer, and their use cannot be recommended.  Each physician who chooses to use drugs in combination with this prosthesis must assure compatibility of the drug with silicone elastomer. Careful hemostasis is important to prevent postoperative hematoma formation. Device should not be implanted until bleeding is under control. Care must be taken to avoid risk of implant puncture during implant or subsequent surgical procedures. Prosthesis structural integrity is required.  Device should not be implanted following modification of its design. A standby device should be available during surgery. Surgeons implanting penile prostheses should be familiar with the currently available techniques for measuring the patient, determining implant size, and performing the surgery.

Potential Complications

Pain, discomfort, edema (implant or incision site), infection, extrusion, displacement/migration, genital hematoma, keloid formation, implant deflation/leakage, inadequate position, fluid accumulation, constipation, hives, fibrosis, granuloma, mobile implant, neuropathy (leg), numbness (heel), suture abscess, and unnecessary incision
See the device manual for detailed information regarding the implant procedure, contraindications, warnings, precautions, and potential complications/adverse events. For further information, call Coloplast Corp and/or consult the company website at
Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

  1. Clinical data on file at Coloplast Corp., and within the device labeling.
  2. M1715N A Patient’s Guide to Testicular Prostheses.

Product codes

Expand to see all variants of the product.

View product codes

Product codes

Product name Item Number CCode Order number Size Eaches/Box
Torosa® 520600 L8699 450-1323 Extra Small 1
Torosa® 520610 Small 1
Torosa® 520610 L8699 450-1325 Small 1
Torosa® 520630 L8699 450-1327 Medium 1
Torosa® 520650 L8699 450-1329 Large 1
Torosa® 520610 L8699 450-1325 Small 1
Torosa® 520630 Medium 1
Torosa® 520650 Large 1
Torosa® 520600 L8699 450-1323 Extra Small 1
Torosa® 520630 L8699 450-1327 Medium 1
Torosa® 520650 L8699 450-1329 Large 1
View desktop version